Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 886283.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/23/2013
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 05/03/2013
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 05/13/2013
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/13/2013 | $0.00 | 05/03/2013 | Serious | |
| Penalty | Z: Issued | 04/23/2013 | $0.00 | 05/03/2013 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Reliable Castings Corporation - Sidney, Ohio: On or about February 5, 2013, the employer failed to assure that the Hunter mold machine was shutdown and procedures for the application of energy control were followed while an employee conducted service and repair tasks to the machine's hopper car. An employee repairing the car was exposed to injuries associated with pinch points when the hopper car unexpectedly moved to its home position during the repair.