Violation Detail
Standard Cited: 19260453 B02 I Aerial lifts.
Inspection Nr: 723141.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 04/30/2013
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/24/2013
Gravity: 10
Report ID: 0936200
Contest Date: 06/18/2013
Final Order: 03/03/2014
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 03/03/2014 | $0.00 | 05/24/2013 | Serious | |
| Penalty | C: Contested | 10/23/2013 | $7,000.00 | 05/24/2013 | Serious | |
| Penalty | Z: Issued | 04/30/2013 | $7,000.00 | 05/24/2013 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.453(b)(2)(i): Lift controls were not tested each day prior to use to determine that such controls were in safe working condition: The employer fails to require aerial lift function tests be conducted as required by the manufacturer prior to use to ensure controls were in safe working condition. This was most recently observed at MCAS Miramar Hangar 7 where an operator did not perform function tests prior to use.