Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 329079.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/13/2012
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 08/12/2012
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 08/03/2012
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/03/2012 | $0.00 | 08/12/2012 | Serious | |
Penalty | Z: Issued | 07/13/2012 | $0.00 | 08/12/2012 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) TRW Automotive , U.S., LLC, on or about 6/21/12: The employer did not provide training to authorized and affected employees to ensure that the energy control program was understood and that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices. Employees perform service and/or maintenance on equipment, including but not limited to, Selective Solder Systems, Shaker, Automated Robot and Assembly Machines.