Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 313498834

Citation: 01001B

Citation Type: Serious

Abatement Status: X

Initial Penalty: $7,000.00

Current Penalty:

Issuance Date: 04/08/2011

Nr Instances: 1

Nr Exposed: 6

Abatement Date: 06/30/2011

Gravity: 10

Report ID: 0627500

Contest Date:

Final Order:

Related Event Code (REC): A

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 04/29/2011 06/30/2011 Serious  
Penalty Z: Issued 04/08/2011 $7,000.00 05/25/2011 Serious  

Text For Citation: 01 Item/Group: 001B Hazard: STRUCK BY

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer does not furnish to each of his employees employment and a place of employment which are free from the recognized hazards of being struck by falling collapsing equipment and materials caused by a furnace explosion which are causing or likely to cause death or serious physical harm to employees: The employer does not provide employee training for safe operation of the draw gas furnace, manufactured by the Electric Furnace Company (EFC), located in the Ball Mill Area. On or about October 18, 2010, at time prior to, employees working in the Ball Mill were operating, maintaining and repairing the draw gas furnace. This condition exposed employees to hazards such as but not limited to; explosion, fire and struck by hazards. Explosion at gas furnace did occur, resulting in an employee fatality. Some feasible means of abatement may include, but are not limited to the following: 1) Provide employees with proper and specific training for operating the draw gas furnace. This training should at a minimum include the following: a) Specific training on written procedures for draw gas furnace operations; b) Specific training conducted by a competent person to operate the draw gas furance; c) assignment of responsibility for employees responsible for draw gas furnace operations; d) Enforcement policy to ensure that employees operating the draw gas furnace follow proper procedures; e) other relevant items to comply with are NFPA 86, 1995, Standard for "Ovens and Furnaces", or equivalent, for the design, installation and operation of the furnace (reference Chapter 1 General, Section 1-5 Operator and Maintenace Personnel Training, 1-5.1, 1-5.2, 1-5.3, 1-5.4, 1-5, 1-5.6) Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation describing the actions it is taking to establish, communicate, and implement a effective training program to ensure employees are been properly trained on the safe operation of the draw gas furnace.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.