Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1845115.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/23/2026
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 07/06/2026
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 02/04/2026
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/04/2026 | $0.00 | 07/06/2026 | Serious | |
| Penalty | Z: Issued | 01/23/2026 | $0.00 | 03/02/2026 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about and at times prior to January 8, 2026, at the establishment located at 1323 South 11th Avenue, Wausau, Wisconsin; the employer did not ensure that a periodic inspection was conducted at least annually for energy control procedures including, but not limited to Dowel Boring Machine (ID 2249), Fiberglass Saw (ID 1057), Mortiser #1, Router Table (ID 0570), Router Table (ID 2496), Tenoner (ID 0148), Wagoma #2 (ID 0260), and Weinig #4 (ID 0166).