Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1840818.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/30/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/05/2025
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 11/20/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/20/2025 | $0.00 | 11/05/2025 | Serious | |
| Penalty | Z: Issued | 09/30/2025 | $0.00 | 11/05/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. At an establishment located at 242 South Pearl Street, in Berlin, Wisconsin, in the Fabrication Area, the employer did not conduct periodic inspections of their energy control procedures to ensure that the procedures and the requirements of this standard were followed. Employees performed servicing and maintenance tasks on equipment including but not limited to, Ermaksan hydraulic brake press and Edwards Elite 110/65 hydraulic ironworker.