Violation Detail
Standard Cited: 19100147 F01 V The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1824373.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/04/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/17/2025
Gravity: 10
Report ID: 0316400
Contest Date:
Final Order: 11/26/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/26/2025 | $0.00 | 11/17/2025 | Serious | |
| Penalty | Z: Issued | 11/04/2025 | $0.00 | 11/17/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(f)(1)(v): All systems were not de-energized and energy control measures reapplied in accordance with paragraph (d) of this section to continue the servicing and/or maintenance: a) Caustic Department, 15696 Energy Road, Proctor, WV 26055: On or about May 11, 2025, employees performed servicing such as tightening bolts on the upper manway cover of the 1A surface condenser that was under an internal pressure of approximately 58 psi, exposing employees to a potential struck by hazard. The condenser was not depressurized and energy control measures were not reapplied before employees began tightening bolts on the upper manway cover. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Translate