Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1819689.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/15/2025
Nr Instances: 1
Nr Exposed: 42
Abatement Date: 09/11/2025
Gravity: 10
Report ID: 0625500
Contest Date: 09/12/2025
Final Order: 05/06/2026
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/06/2026 | $0.00 | 09/11/2025 | Serious | |
| Penalty | C: Contested | 09/12/2025 | $0.00 | 09/11/2025 | Serious | |
| Penalty | Z: Issued | 08/15/2025 | $0.00 | 09/11/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about April 21, 2025, at bread oven infeed conveyor (P12), a specific procedure for locking out the sources of energy was not developed.