Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1807778.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/04/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/02/2025
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 04/21/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/21/2025 | $0.00 | 05/02/2025 | Serious | |
| Penalty | Z: Issued | 04/04/2025 | $0.00 | 05/02/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. On or about March 4, 2025, at an establishment located at 1800 North Point Drive, in Stevens Point, Wisconsin; the back side of the Bell Howell Mail Processing Machine, Model Ascender 16, Serial Number: A584850/0485A was an exposed belt and pulley drive used to power the driver rollers to move envelopes exposing employees to caught in between hazards.