Violation Detail
Standard Cited: 19101000 A02 Air contaminants.
Inspection Nr: 1805530.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/27/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/10/2025
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 07/24/2025
Related Event Code (REC): C
Emphasis:
Substance: 9130
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/24/2025 | $0.00 | 11/10/2025 | Serious | |
Penalty | Z: Issued | 06/27/2025 | $0.00 | 07/17/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of respirable dust listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 5 mg/m3: Employee exposures to particulates not otherwise regulated (PNOR) respirable fraction exceeded the Permissible Exposure Limit (PEL) of 5.00 mg/m3 listed in Table Z-1 for instances such as, but not limited to: a) On or about March 5, 2025, the operator performing abrasive blasting in the Upsetter Building was exposed to respirable dust at an 8-hour time-weighted average (TWA) of 30.40 mg/m3 during the 402 minute sampling period. This is approximately 6.08 times the permissible exposure limit (PEL) of 5.0 mg/m3. Exposure calculations include a zero exposure increment for the 78 minutes not sampled.