Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1804949.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/15/2025
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 06/11/2025
Gravity: 5
Report ID: 0317300
Contest Date:
Final Order: 06/12/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/12/2025 | $0.00 | 06/11/2025 | Serious | |
Penalty | Z: Issued | 05/15/2025 | $0.00 | 06/11/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this sec a) 612 Christiana Ave., Wilmington, DE 19801 (Line-2): On or about February 20, 2025, and days prior thereto, employees were exposed to struck by hazards while conducting servicing and maintenance of the Hamer Brand model RPM Robotic Palletizer, without specific lockout/tag out procedures.