Violation Detail
Standard Cited: 19100134 M02 I C Respiratory Protection.
Inspection Nr: 1803994.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/14/2025
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 08/06/2025
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 08/05/2025
Related Event Code (REC):
Emphasis:
Substance: 9000
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/05/2025 | $0.00 | 08/06/2025 | Serious | |
Penalty | Z: Issued | 07/14/2025 | $0.00 | 08/06/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.134(m)(2)(i)(C): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the specific make, model, style and size of respirator tested: On or about February 11, 2025 and at times thereafter, the employer did not ensure fit test records included the model and size of the respirator used for fit testing. The employer required employees to wear tight fitting elastomeric respirators to protect against exposure to respirable crystalline silica while working in dry set up, operating mixers, and during pump out activities.