Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1794916.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,550.00
Current Penalty: $0.00
Issuance Date: 05/08/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/26/2025
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/03/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/03/2025 | $0.00 | 06/26/2025 | Serious | |
Penalty | Z: Issued | 05/08/2025 | $16,550.00 | 06/26/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29CFR 1910.147(c)(4)(ii)[B], 29CFR 1910.147(c)(4)(ii)[C], and 29CFR 1910.147(c)(4)(ii)[D]: On or about December 13, 2024, the Employer provided general procedures and training on the hazardous energy control (LOTO), but the written cleaning procedures for the Pot�Mixer-Mepaco-02 machine, Model 170, Serial number 462 did not contain the information set forth in 1910.147(c)(4)(ii)(B), (C), & (D).