Violation Detail
Standard Cited: 19100147 F02 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1780162.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/14/2025
Nr Instances: 1
Nr Exposed: 11
Abatement Date: 02/18/2025
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/04/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/04/2025 | $0.00 | 02/18/2025 | Serious | |
Penalty | Z: Issued | 01/14/2025 | $0.00 | 02/18/2025 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(f)(2)(i): Whenever outside servicing personnel are to be engaged in activities covered by the scope and application of this standard, the on-site employer and the outside employer shall inform each other of their respective lockout or tagout procedures. a) On or before 11/14/2024, the employer did not inform their 3rd party contractor (KRC) who provides servicing and maintenance operations such as preventative maintenance and maintenance on equipment such as but not limited to; the A36 Toshiba CNC machine (model # BP-150.R22, SN 914853), the A37 Toshiba CNC machine (model # BTH-130.R24, SN 915630), and the A38 Toshiba CNC machine (model # BTH-130.R24, SN 915663) , a copy of their respective lockout procedures in that McSwain had not developed an energy control program that included energy control procedures, training and periodic inspections and procedures for outside contractors to follow.