Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1739968.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $0.00
Issuance Date: 07/15/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/30/2024
Gravity: 10
Report ID: 0523300
Contest Date: 08/26/2024
Final Order: 11/29/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/29/2024 | $0.00 | 12/30/2024 | Serious | |
Penalty | C: Contested | 09/10/2024 | $16,131.00 | 08/05/2024 | Serious | |
Penalty | Z: Issued | 07/15/2024 | $16,131.00 | 08/05/2024 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about February 24, 2024, the employer failed to provide training to ensure operators of the Press 23 cell understood the purpose and function of the energy control program safely engage in maintenance and services activities.