Violation Detail
Standard Cited: 19260451 G04 II General requirements.
Inspection Nr: 1737925.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/21/2024
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 09/13/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/13/2024 | $0.00 | Serious | ||
Penalty | Z: Issued | 08/21/2024 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.451(g)(4)(ii): The top edge height of toprails or equivalent member on supported scaffolds manufactured or placed in service after January 1, 2000, had not been installed between 38 inches (0.97 m) and 45 inches (1.2 m) above the platform surface. The top edge height on supported scaffolds manufactured and placed in service before January 1, 2000, had not been between 36 inches (0.9 m) and 45 inches (1.2 m). On or about March 22, 2024, HEINE BROTHERS TUCKPOINTING, INC. did not ensure that guardrails served as adequate fall protection for two employees tuckpointing a residential building at 71 Crestwood Drive in Clayton, Missouri. Crossbracing served as midrails, and no toprails were installed thus exposing two employees to fall hazards from heights of approximately 30 feet.