Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
Inspection Nr: 1723277.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/07/2024
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 06/03/2024
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 05/22/2024
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/22/2024 | $0.00 | 06/03/2024 | Serious | |
| Penalty | Z: Issued | 05/07/2024 | $0.00 | 06/03/2024 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.179(j)(2): Overhead cranes were not inspected on frequent intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: a.) Custom Valve Repair, LLC 3589 Harlansburg Road New Castle, PA 16101, on or about 01/25/2024, and times prior thereto: the company had not performed frequent inspections on the cranes. Cranes include, but is not limited to, Reading 15-ton crane (Serial number 18495).