Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1720717.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,067.00
Current Penalty: $0.00
Issuance Date: 06/12/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/19/2024
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 07/09/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/09/2024 | $0.00 | 08/19/2024 | Serious | |
Penalty | Z: Issued | 06/12/2024 | $8,067.00 | 07/17/2024 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about January 11, 2024, employees were exposed to machine hazards associated with moving parts and electrical hazards during servicing and maintenance of the hydraulic powered pump within the Flow Corporation I-4800 Water Table Cutter, S/N: 378046, located in the production area of the facility. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.