Violation Detail
Standard Cited: 19100334 A02 II Use of equipment.
Inspection Nr: 1705174.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/25/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0626300
Contest Date:
Final Order: 04/01/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/01/2024 | $0.00 | Serious | ||
| Penalty | Z: Issued | 03/25/2024 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: (a) On or about October 23, 2023, and at times prior thereto, in the production area, where employees were exposed to electric shock hazards when they operated a DeWalt miter saw that had a frayed power cord and the saw was not taken out of service.