Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1690883.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $0.00
Issuance Date: 08/29/2023
Nr Instances: 2
Nr Exposed: 14
Abatement Date: 09/13/2023
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 09/26/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/26/2023 | $0.00 | 09/13/2023 | Serious | |
Penalty | Z: Issued | 08/29/2023 | $15,625.00 | 09/13/2023 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) On or about August 23, 2023, hazardous energy control procedures for the Toyokoki Press Brakes did not include a specific statement of the intended use pursuant to 29 CFR 1910.147(c)(4)(ii)(A). b) On or about August 23, 2023, the hazardous energy control procedure for the Toyokoki Press Brakes did not state how the authorized employees would verify a total de-energized state pursuant to 29 CFR 1910.147(c)(4)(ii)(D).