Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1689302.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/28/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/15/2023
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 11/02/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/02/2023 | $0.00 | 12/15/2023 | Serious | |
| Penalty | Z: Issued | 09/28/2023 | $0.00 | 10/25/2023 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):( a. On or about August 4, 2023, an employee was exposed to a struck-by hazard when setting up a die on a mechanical power press without the machine being isolated from its energy sources. b. On or about July 26, 2023, an employee was exposed to caught-by hazards when setting up a coiling machine without the machine being isolated from its energy source.