Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1684133.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/12/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/01/2024
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 02/05/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/05/2024 | $0.00 | 03/01/2024 | Serious | |
Penalty | Z: Issued | 01/12/2024 | $0.00 | 03/01/2024 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i):The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about July 14, 2023, the employer did not conduct a periodic inspection of the developed and documented energy control procedure for the Dake Bow 2 Vertical Press Machine at least annually to ensure that the procedure and the requirements of the standard were being followed by employees engaged in service and maintenance activities, such as but not limited to, setting up the dies inside the press.