Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1656794.015
Citation: 01001B
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/18/2023
Nr Instances: 1
Nr Exposed: 13
Abatement Date:
Gravity: 5
Report ID: 0419730
Contest Date:
Final Order: 08/29/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/29/2023 | $0.00 | Other | ||
| Penalty | Z: Issued | 07/18/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a) a) Jobsite: 14700 Aerospace Pkwy, Orlando, FL 32832, Warehouse router room: A guard was not installed on the AXYZ CNC Router Machine Model # 4016 Serial # 4708-4598 pully system, exposing employees to a pinch point hazard, on or about March 13, 2023. No abatement certification or documentation required for this item.