Violation Detail
Standard Cited: 19101026 F01 I
Inspection Nr: 1639299.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,938.00
Current Penalty: $0.00
Issuance Date: 05/08/2023
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 08/21/2023
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 06/01/2023
Related Event Code (REC): C
Emphasis:
Substance: 0689
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/01/2023 | $0.00 | 08/21/2023 | Serious | |
Penalty | Z: Issued | 05/08/2023 | $10,938.00 | 06/02/2023 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.1026(f)(1)(i): Where feasible engineering and work practice controls would not reduce employee exposure to chromium (VI) to or below the permissible exposure limit, the employer did not apply these feasible controls to reduce employee exposures to the lowest chromium (VI) levels achievable: On or about February 24, 2023, a welder in the MDS area of the SST department was exposed to an 8-hour time weighted average (TWA) of 8.6 �g/m3 for chromium (VI), approximately 1.725 times the Permissible Exposure Limit (PEL) of 5.0 �g/m3. The exposure level was derived from a sample collected over a 414 minutes sampling period with zero exposure assumed for the unsampled period of 66 minutes. Engineering and administrative controls were not implemented to reduce exposures below the PEL.