Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1607618.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/09/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/13/2023
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 12/27/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/27/2022 | $0.00 | 01/13/2023 | Serious | |
| Penalty | Z: Issued | 12/09/2022 | $0.00 | 01/13/2023 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about July 13, 2022, an employee was working under the Schelling cut-to-size saw, trouble shooting an air leak at the rest position of the saw carriage. The saw was not deenergized, locked out, and the saw carriage not blocked to prevent the saw from returning to the home position. This exposed the employee(s) to a struck-by and crushing hazard. The employer failed to implement energy control application steps as the machines were not isolated from all energy sources [per the 1910.147(d)(3) requirements]. As a result, the remaining applicable energy control elements, involving LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards.
Translate