Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1606228.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/28/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/28/2023
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 01/18/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/18/2023 | $0.00 | 04/28/2023 | Serious | |
Penalty | Z: Issued | 12/28/2022 | $0.00 | 01/25/2023 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) Tonnard Manufacturing Corporation, Bay 3 press area, on or about 07/06/2022 and times prior thereto: Employees perform service and maintenance on machinery including, but not limited to, hydraulic presses. Annual periodic inspections of the lockout tagout procedures were not conducted with authorized employees.