Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1600823.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/19/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 10/11/2022
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 10/12/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/12/2022 | $0.00 | 10/11/2022 | Serious | |
Penalty | Z: Issued | 09/19/2022 | $0.00 | 10/11/2022 | Repeat |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Laminator Line No. 1, Black Brothers brand Model 775 Glue Spreader; Employees perform manual cleaning tasks on equipment including the upper glue spreader feed rollers, lower coating rollers and lower doctor rollers without affixing lockout or tagout device(s) to electrical and pneumatic energy isolation points. Menard, Inc. was previously cited for a violation of this occupational safety and health standard 29 CFR 1910.147(d)(4)(i) which was contained in OSHA inspection number 1292018, citation number 1, item number 4, group c, and was affirmed as a final order on September 6, 2019, with respect to a workplace located at 5231 Kane Road, Eau Claire, WI 54703.