Violation Detail
Standard Cited: 19100134 G01 I A Respiratory Protection.
Inspection Nr: 1596239.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/21/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/20/2022
Gravity: 1
Report ID: 0728500
Contest Date:
Final Order: 11/17/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/17/2022 | $0.00 | 12/20/2022 | Serious | |
| Penalty | Z: Issued | 10/21/2022 | $0.00 | 11/17/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) At a worksite located at 1921 West US Highway 50, Lone Jack, MO 64070, an employee was exposed to respiratory hazards associated with wearing of a respirator. The employer required the use of tight fitting respirators when accessing a container which contained a storage area for dry ice (carbon dioxide). The employee was wearing a tight fitting respirator while having facial hair that came between the sealing surface of the respirator and the employee's face.