Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1582543.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/06/2022
Nr Instances: 1
Nr Exposed: 100
Abatement Date:
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 06/24/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/24/2022 | $0.00 | Serious | ||
| Penalty | Z: Issued | 06/06/2022 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(e)(1)(i):Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) The Flexitrol Work Area: On or about March 9, 2022, an employee was exposed to unguarded rotating horizontal belt on the Spool Wiring system. The pulley was located less than seven (7) feet from the floor.