Violation Detail
Standard Cited: 19260453 B02 IX Aerial lifts.
Inspection Nr: 1579359.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 09/01/2022 2
Initial Penalty: $0.00
Current Penalty: $13,052.00
Issuance Date: 08/08/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 09/01/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/01/2022 | $13,052.00 | 09/01/2022 | Serious | |
Penalty | Z: Issued | 08/08/2022 | $0.00 | 09/01/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.453(b)(2)(ix): Lower controls were not provided for overriding the upper controls: (a) At the RSU #1747 site, on or about February 18, 2022 and at times prior thereto, the lower lift controls of the Genie S-60X telescopic boom lift were not capable of overriding the upper controls, exposing employees to struck-by and fall hazards.