Violation Detail
Standard Cited: 19100147 C04 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1569638.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/17/2022
Nr Instances: 1
Nr Exposed: 12
Abatement Date:
Gravity: 10
Report ID: 0213400
Contest Date:
Final Order: 07/13/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/17/2022 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a. 1900 South Ave., Staten Island, NY The employer did not establish specific procedures for employees and contractors required to utilize hazardous energy control. Employees and contractor employees engaged in the repair of heavy equipment that included, but was not limited to John Deere, Model 360G Excavators, performed Lockout/Tagout procedures where the employer did not provide specific Hazardous Energy Control (LOTO) procedure for each type of equipment. Violation occurred on or about December 17, 2021 and thereafter