Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1560900.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,151.00
Current Penalty: $0.00
Issuance Date: 04/19/2022
Nr Instances: 1
Nr Exposed: 11
Abatement Date: 05/10/2022
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 05/10/2022
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/10/2022 | $0.00 | 05/10/2022 | Serious | |
Penalty | Z: Issued | 04/19/2022 | $10,151.00 | 05/10/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 20, 2021, procedures were not developed to control the residual energy from the rotating auger in the Hobart Chopper, Model 4046, when employees were unjamming the chopper.