Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1559355.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/25/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 04/13/2022
Gravity: 10
Report ID: 0111500
Contest Date:
Final Order: 03/18/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/18/2022 | $0.00 | 04/13/2022 | Serious | |
| Penalty | Z: Issued | 02/25/2022 | $0.00 | 04/13/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: MCCAUSLAND GREENHOUSE: On/or about October 21, 2021, the hazardous energy control lockout/tagout procedures were not written in step-by-step machine specifics for the employees during servicing and maintenance of equipment, such as (but not limited to) main panel/manual switch for the Bay 18 east in the McCausland greenhouse. On this day, the shirt sleeve of an employee replacing a bolt in the drive shaft at Bay 18 East in the McCausland greenhouse was caught in the drive shaft when the energy source had been turned back onto automatic and fell approximately 18 feet resulting in broken bones.
Translate