Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1557487.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/08/2022
Nr Instances: 1
Nr Exposed: 10
Abatement Date:
Gravity: 5
Report ID: 0317700
Contest Date:
Final Order: 03/08/2022
Related Event Code (REC): C
Emphasis:
Substance: 2440
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/08/2022 | $0.00 | Serious | ||
| Penalty | Z: Issued | 02/08/2022 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a) An employee who was required to use a tight-fitting facepiece respirator while working in the blender area on the third floor was not annually fit tested, on or about September 30, 2021. CORRECTED DURING INSPECTION