Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1556845.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/11/2022
Nr Instances: 2
Nr Exposed: 7
Abatement Date: 03/03/2022
Gravity: 10
Report ID: 0111700
Contest Date:
Final Order: 03/07/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/07/2022 | $0.00 | 03/03/2022 | Serious | |
Penalty | Z: Issued | 02/11/2022 | $0.00 | 03/03/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a.) Split Steel Cell - On or about October 7, 2021, the OJIM splitter operators were not utilizing energy isolating devices to isolate the machines from electrical, pneumatic, hydraulic and stored energy sources during tool changes where operators were reaching into energized machines to perform this task. b.) Split Steel Cell, OJIM Splitter Machine SP-011 - On or about October 5, 2021, maintenance employees used a wooden block inside the machine to isolate the stored energy in the upper ram assembly that was not located and secured in a manner to isolate the energy source.