Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1549964.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/14/2022
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 03/11/2022
Gravity: 10
Report ID: 0626000
Contest Date: 03/10/2022
Final Order: 07/01/2022
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | W: Empr Withdrew | 07/01/2022 | $0.00 | 03/11/2022 | Serious | |
| Penalty | C: Contested | 03/16/2022 | $0.00 | 03/11/2022 | Serious | |
| Penalty | Z: Issued | 02/14/2022 | $0.00 | 03/11/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about August 23, 2021 at this workplace, employees who perform repair operations on semi-trucks and trailer container chassis are exposed to backing-up caught-in between hazards. Energy control procedures did not specifically outline the procedural steps to shut down and isolate a semi-truck.
Translate