Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1538407.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/19/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/10/2022
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 12/14/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/14/2021 | $0.00 | 01/10/2022 | Serious | |
| Penalty | Z: Issued | 11/19/2021 | $0.00 | 01/10/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Plant #8 - On or about June 6, 2021, an employee was exposed to machine hazards associated with exposed and live wires when the employee was clearing plastic debris from the Poly-Cell Film Making Bubble Machine #2 Model#PCS-1930HPA. The employer failed to implement energy control application steps as the machine power was not shut down to perform servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], Lockout/Tagout device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.