Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1534705.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/07/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/04/2022
Gravity: 10
Report ID: 0418300
Contest Date: 01/06/2022
Final Order: 07/05/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 07/05/2022 | $0.00 | 01/04/2022 | Serious | |
| Penalty | C: Contested | 01/14/2022 | $0.00 | 01/04/2022 | Serious | |
| Penalty | Z: Issued | 12/07/2021 | $0.00 | 01/04/2022 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedure did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about 6/7/2021 - 515 Tyson Road, Ashland, Alabama, in the Second Processing Department, employees using the ECP for the Leg Quarter Hopper Scale, Line #1 and #2 to access the point of operation to perform work were exposed to machine hazards such as struck by, and caught by from energized parts because the ECP did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.
Translate