Violation Detail
Standard Cited: 19100147 C07 III B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1532302.015
Citation: 01001B
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $27,033.00
Current Penalty: $0.00
Issuance Date: 09/17/2021
Nr Instances: 7
Nr Exposed: 10
Abatement Date: 12/03/2021
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/07/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/07/2021 | $0.00 | 12/03/2021 | Repeat | |
Penalty | Z: Issued | 09/17/2021 | $27,033.00 | 10/22/2021 | Repeat |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: On or about May 21, 2021, the employer failed to ensure that employees were trained on effective lockout/tagout procedures based on the programs requirements and any noted deficiencies. Machinery that would fall under this type of program, include but is not limited to the low pressure tilt molds 1-7. Energy sources such as electric, pneumatic, mechanical and gravitational. NOTE: The employer was previously cited for a violation of this occupational safety and health standard or it's equivalent standard which was contained in OSHA Inspection #1517390, citation 1, item 2b, which was affirmed as final order on April 16, 2021 with respect to the same workplace location.