Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1527478.015
Citation: 01001B
Citation Type: Other
Abatement Date: 10/29/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/24/2021
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 10/15/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/15/2021 | $0.00 | 10/29/2021 | Other | |
Penalty | Z: Issued | 09/24/2021 | $0.00 | 10/18/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Building No. 21, Sortation Department; On or about April 22, 2021, equipment was not isolated from energy sources prior to an employee accessing automated pallet conveyor(s) to perform jam clearing activities at upper transfer car station no. 6.