Violation Detail
Standard Cited: 19260451 B08 General requirements.
Inspection Nr: 1527463.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/24/2021
Nr Instances: 2
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0419700
Contest Date: 11/12/2021
Final Order: 05/31/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/31/2023 | $0.00 | Serious | ||
| Penalty | C: Contested | 11/19/2021 | $0.00 | Serious | ||
| Penalty | Z: Issued | 09/24/2021 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.451(b)(8):At all points of a scaffold where the platform changes direction, such as turning a corner, the platform that rests on a bearer at an angle other than a right angle was not laid first: a. On the fourth and fifth levels of the front exterior scaffold system, at the northwest corner, at 22 Ocean Ridge Boulevard North in Palm Coast Florida: On or about April 15, 2021, the employer failed to ensure employees of subcontractor Isel Herrera were not exposed a fall hazard from loose planking of up to 32 feet fall hazard when performing stucco work, in that the plank placed at the corner at a 45 degree angle was not laid first on the bearers.
Translate