Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1527370.015
Citation: 01001B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/24/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/21/2021
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 10/19/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/19/2021 | $0.00 | 10/21/2021 | Other | |
| Penalty | Z: Issued | 09/24/2021 | $0.00 | 10/21/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about 04/17/2021 - Strapper #5 at Line #1 in the Strapper #2 position, authorized employees were exposed to struck-by and thermal hazards when performing periodic maintenance activities such as, but not limited to, cleaning up strapper dust in the compression bar area and dismantling the R.H. heater slide guide to eliminate dirt and the written lockout/tagout procedure number 80 for the Auto Strappers did not clearly and specifically outline the requirements for controlling the potentially hazardous compressed air and residual thermal energy.