Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1522211.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,873.00
Current Penalty: $0.00
Issuance Date: 06/08/2021
Nr Instances: 4
Nr Exposed: 15
Abatement Date:
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 06/30/2021
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/30/2021 | $0.00 | Serious | ||
| Penalty | Z: Issued | 06/08/2021 | $12,873.00 | Serious | 
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources: On or about March 16, 2021, energy isolating devices including the electrical cords and pneumatic hoses on taper machines were not disconnected so as to isolate these taper machines from energy sources during the replacing of tape rolls and clearing tape jams.
 Translate
Translate