Violation Detail
Standard Cited: 19100132 D01 General requirements.
Inspection Nr: 1514501.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,901.00
Current Penalty: $0.00
Issuance Date: 05/18/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/14/2021
Gravity: 5
Report ID: 0213100
Contest Date:
Final Order: 06/21/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/21/2021 | $0.00 | 06/14/2021 | Serious | |
| Penalty | Z: Issued | 05/18/2021 | $3,901.00 | 06/14/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE)(a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)(DESCRIBE HAZARD(S) WHERE NECESSARY) a) 10 Coleman Rd. Garrison, NY- On or about December 7, 2020 , a workplace hazard assessment was not conducted for an employee who was servicing a home heating system (oil burner furnace) when attempting to ignite the system when a puffback occurred. The employee received 2nd and 3rd degree burns to the face, hands and head resulting in an in-patient hospitalization.
Translate