Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1506004.015
Citation: 01001B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/04/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 07/01/2021
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 06/28/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/28/2021 | $0.00 | 07/01/2021 | Serious | |
| Penalty | Z: Issued | 06/04/2021 | $0.00 | 07/01/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) Lamination department, Hymmen laminator 1A102: The company's established alternative energy isolation procedures used during lamination changes and lamination tear repairs did not identify steps for shutting down, isolating, blocking and securing the energy sources of the acid rollers and the adhesion rollers.