Violation Detail
Standard Cited: 19100177 D04 II Servicing multi-piece and single piece rim wheels.
Inspection Nr: 1493292.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 03/22/2021 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/24/2021
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 03/18/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/18/2021 | $0.00 | 03/22/2021 | Serious | |
Penalty | Z: Issued | 02/24/2021 | $0.00 | 03/22/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.177(d)(4)(ii):The employer did not furnish an air line assembly which included an in-line valve with a pressure gauge or a presettable regulator for inflating tires on rim wheels: a) At the facility, in front of and in the maintenance shop, on or about September 8, 2020, the employer did not insure the use of in-line regulators for air lines, used by employees, to inflate rim tires, thus exposing employees to struck-by hazards.