Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1477106.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/13/2020
Nr Instances: 2
Nr Exposed: 46
Abatement Date: 11/06/2020
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 10/29/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/29/2020 | $0.00 | 11/06/2020 | Serious | |
| Penalty | Z: Issued | 10/13/2020 | $0.00 | 11/06/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. a). Wire Bound Department: Lines 1-10, 13, 14 (Discharge end of the Rock Fastener) - On or about and times prior to June 2, 2020 there was an horizontal shaft that was not guarded on the discharge end of the rock fastener, thus exposing employees to an caught-in hazard. b). Wire Bound Department: Lines 1-10, 13, 14 (Between the Rock & Blank Fastener) - On or about and times prior to June 8, 2020, there was an horizontal shaft that was not guarded on the rear of the Blank Fastener machine, thus exposing employees to an caught-in hazard.
Translate