Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1471984.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/22/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/30/2020
Gravity: 5
Report ID: 1032500
Contest Date:
Final Order: 06/18/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/18/2020 | $0.00 | 09/30/2020 | Serious | |
Penalty | Z: Issued | 05/22/2020 | $0.00 | 07/10/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The employer had not developed, documented and utilized specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) PB-15 "Dino" Svartek Grinder: On or about April 7, 2020 and at times prior thereto the documented procedures for the control of hazardous energy on the PB-15 "Dino" grinder did not identify the shovel cylinder and guide rods as other required machinery that must be locked out before beginning maintenance on the grinder. Note) Certification of corrective action is required for this item.