Violation Detail
Standard Cited: 19260651 J01 Specific Excavation Requirements.
Inspection Nr: 1466533.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/31/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/26/2020
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 08/14/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/14/2020 | $0.00 | 08/26/2020 | Serious | |
Penalty | Z: Issued | 07/31/2020 | $0.00 | 08/26/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: (a) February 28, 2020; employees worked without cave-in protection in an excavation of Type C soil adjacent to soil fissuring on the east wall, exposing employees to engulfment hazards. The excavation measured approximately 6.3' deep, 6' wide, 20' long, and had nearly vertical walls. NOTE: Abatement certification and documentation are required for this item.