Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1460769.015
Citation: 01001B
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/24/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity:
Report ID: 0521700
Contest Date:
Final Order: 05/19/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/19/2020 | $0.00 | Other | ||
| Penalty | Z: Issued | 04/24/2020 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) Bean Room - On or about January 31, 2020, the employer failed to provide training to each affected employee to ensure the purpose and function of the energy control program were understood. Employees were thereby exposed to injuries associated with the unexpected energization and/or startup of the equipment.